Drimit Link Open Standard

2 Debounce and False Connection Prevention (20ms minimum stabilization)

1 Mechanical Bounce Detection Algorithm

  - Multi-Stage Debounce Implementation (Hardware + Software)
  - Contact Resistance Threshold Monitoring (>1MΩ open, <100mΩ closed)
  - Signal Edge Rate Analysis (Bounce vs intentional connection)
  - Temperature Compensation for Contact Resistance

2 Signal Stabilization Validation Criteria

  - Minimum Stable Period: 20ms continuous contact
  - Maximum Acceptable Resistance Variation: ±10mΩ
  - Power Rail Stability Requirements: ±2% voltage tolerance
  - Communication Link Establishment: CAN bus idle detection

3 False Positive Rejection Mechanisms

  - Partial Connection Detection (Some pins connected, others open)
  - Intermittent Contact Filtering (Rapid connect/disconnect cycles)
  - Environmental Noise Immunity (EMI, vibration, temperature)
  - Cross-Pin Short Circuit Detection and Protection

4 Connection Quality Scoring Algorithm

  - Contact Resistance Score (0-100 based on pin resistance)
  - Signal Integrity Score (Eye diagram analysis, jitter measurement)
  - Power Delivery Quality (Voltage regulation, ripple, noise)
  - Magnetic Alignment Score (Position accuracy within tolerance)
  - Overall Connection Health Index (Weighted composite score)

Algorithm Required: Debounce logic flowchart with timing parameters

Pseudocode Required: Bounce detection and quality scoring algorithms

Configuration Table Required: Debounce timing parameters by connection type